H1 compliance

H1 VM1 & VM2 Compliance Modelling

A performance-based pathway to H1 compliance that gives design teams flexibility without compromising architectural intent.

H1 compliance modelling is a performance-based method for demonstrating compliance with the H1 Energy Efficiency Clause of the New Zealand Building Code. Using the H1/VM1 and H1/VM2 modelling pathways, the thermal performance of a building can be assessed using detailed energy modelling rather than relying solely on prescriptive construction requirements.

Based in Wānaka, Performance Building Consultants provides H1 compliance modelling services in Wānaka, Queenstown, the Southern Lakes and across Otago, as well as working with architects, designers and builders throughout New Zealand.

Flexible H1 compliance through modelling

H1 modelling provides greater flexibility in how a building achieves the required level of thermal performance. Instead of treating each building element in isolation, the modelling approach allows the overall performance of the thermal envelope to be assessed.

This can be particularly useful for projects with larger areas of glazing, complex building forms or bespoke architectural designs, where standard construction approaches may be restrictive.

By modelling the building as a whole, design teams can investigate different combinations of insulation, glazing, shading and other envelope elements to find a solution that meets H1 requirements while maintaining the intended architectural design.

H1 VM1 and VM2

The appropriate H1 verification method depends on the type and size of the building.

H1/VM1

Applies to all housing and to other buildings with an occupied floor area of 300 m² or less.

H1/VM2

Applies to certain non-residential buildings with an occupied floor area greater than 300 m².

I can help determine the appropriate H1 modelling pathway for your project and provide the modelling and documentation required to demonstrate compliance.

H1 compliance and building performance

H1 compliance modelling can be integrated with broader energy modelling and building performance analysis. This means the same modelling process can be used to investigate both compliance and wider design objectives such as thermal comfort, heating demand and energy efficiency.

Rather than treating H1 compliance as a separate exercise at the end of the design process, modelling can be used earlier to compare design options and identify opportunities to improve performance.

This can help project teams:

  • Demonstrate compliance with the H1 Energy Efficiency Clause
  • Compare different insulation and glazing strategies
  • Assess the impact of shading and solar gains
  • Optimise the thermal performance of the building envelope
  • Maintain architectural intent while meeting performance requirements
  • Identify cost-effective ways to achieve compliance
  • Reduce the need for design changes later in the project

H1 modelling for Wānaka, Queenstown and throughout New Zealand

For projects in Wānaka and Queenstown, where cold winters and significant solar gains can have a substantial impact on building performance, H1 modelling provides a useful way to assess the building against the local climate.

I work with architects, designers and builders to provide clear, efficient and project-specific H1 compliance modelling support, helping design teams understand the requirements and make informed decisions throughout the design process.

Whether you need H1/VM1 modelling for a new home or small building, or H1/VM2 modelling for a larger non-residential project, I can help provide a practical pathway to demonstrating compliance.

Find the right H1 pathway

Get in touch to discuss your project or to find out which H1 compliance pathway is appropriate for your building.

Get in touch
Contact

Let’s talk about your project.

Send a few details and we’ll come back with the right service pathway, likely scope, and next steps.